Horstmann H37XL Channelplus Electronic Central Heating Programmer Series 2 - 3 channel, 7 day

£9.9
FREE Shipping

Horstmann H37XL Channelplus Electronic Central Heating Programmer Series 2 - 3 channel, 7 day

Horstmann H37XL Channelplus Electronic Central Heating Programmer Series 2 - 3 channel, 7 day

RRP: £99
Price: £9.9
£9.9 FREE Shipping

In stock

We accept the following payment methods

Description

Once the secondary circulation is out of the picture, the Zone 1* connections would be wired to the Central heating terminals of the Heatlink and Zone 2* connections to the Hot Water terminals. You should identify what each of the wires connected to the Horstmann does from the diagram you have posted, and then move them to the terminal that has the same function at the Heatlink. Tighten the two 'captive' retaining screws to fix the unit securely, then switch on the mains supply. INITIAL SET-UP I'm not sure I understand what you mean by the above, because the switching elements of the Channelplus 37xl and the Heatlink work in exactly the same manner.

The programmer is fitted with a non-rechargeable, non-serviceable long life battery, which will maintain the programmed time settings with the mains supply disconnected. All ChannelPlus XL controls are fitted with battery reserve which maintains programmed times in the event of a mains power failure. REAR VIEW OF CHANNELPLUS XL PROGRAMMER I have only ever once come across a system with a 'central heating off' connection that contained a very uncommon type of motorised valve (MoMo, or Motor on, Motor off) that requires this connection to close it. Then, once the common at the Heatlink is connected, both devices will function identically to each other.

Write a review

Lower the front flap of the unit. On third Channel press the ADVANCE(Enter) and SELECT(Blue) buttons together then release the buttons and the programmer will return to the preset factory settings.

Once the mains power has been switched on the ChannelPlus H37XL Series 2's display will illuminate. The programmer has a number of pre-programmed functions to assist the installation, which are detailed below;

Rating

I am assuming here that you are referring to a 'Secondary Hot Water Circulator' that circulates the domestic hot water around a ring main so that hot water is available instantly at each outlet, then the answer is yes you will need to move that to another timer. This is the first time I have come across this in a domestic property, but can understand why if you have an unusually long pipe run.



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop